Eutectic plates

Tuesday, September 15th, 2009

20090915 Eutectic plates, also known as cold plates, have been used in the transport industry for many years. They are charged overnight with an electric powered refrigeration compressor while a truck is parked. The next day, the truck is un-plugged, and the shipment is keep cold all day with the re-usable eutectic solution inside the plate.

It is just that simple. Dole Refrigerating Co. will help you estimate the hardware needed for your next truck body or to retrofit your current body. Visit their website www.doleref.com for more information.

Eutectic Cold Plate Systems

Thursday, September 10th, 2009

Dole Refrigeration is the leading manufacturer of Eutectic Cold Plate Systems and Dual Contact Freezers.

Dole’s Dual Contact Freezer

Monday, July 27th, 2009

Dole’s Dual Contact Freezer is the answer to virtually any in-plant freezing need. Constructed in a number of different of sizes, the Dual Contact Freezer line uses established technology for better heat transfer. Designed with a strong steel frame and enclosed with an optional insulated cabinet in some models, Dole’s Dual Contact Freezers contain hydraulically controlled Thermo-Film vacuum steel plates or extruded aluminum plates. Dole presents both horizontal and vertical contact freezing systems along with remote and self-contained units. More information on Dole’s Dual Contact Freezer product line can be found in the catalogs below or by contacting Dole.

Marine Refrigeration

Monday, July 27th, 2009

What is Marine Refrigeration?  The major parts of this refrigeration system include the refrigerant, a compressor, a condenser, and plates inside the refrigeration unit.

What is Marine Refrigeration?  The major parts of this refrigeration system include the refrigerant, a compressor, a condenser, and plates inside the refrigeration box.

The compressor in the marine refrigeration system is part of a closed loop pumping refrigerant through the system and through the evaporator plate in the ice box. The compressor has two sides- the High side or discharge side. The discharge side pumps refrigerant into the condenser. The cold plates in the fridge space have either expansion valves that separate the low and high pressure sides of the refrigeration system.

The refrigerant in the compressor starts as a gas. The compressor condenses the refrigerant gas, from low pressure to high pressure between 100-150 psi. When the pressure is increased like this its temperature is raised significantly. This hot high pressure refrigerant is then fed to a condenser, where it is cooled and turned into a liquid. The condenser is cooled by either air or water. The refrigerant is now a cool high pressure liquid and is fed to an evaporator plate inside the boats refrigerator box.

The evaporator plate in the marine refrigeration system takes the refrigerant from the condenser and then boils it rapidly & evaporates it back to a gas, at a very low temperature. This transformation soaks up vast amounts of heat from the evaporator which in turn eliminates heat from the insulated refrigeration box- lowering its temperature. The BTU is the amount of heat eliminated. From the evaporator plate the refrigerant is returned to the low side of the compressor, to start the process again.

Evaporator or Holding Plates

Marine refrigeration systems use either an evaporator plate or a holding plate in the boat’s refrigeration space or freezer space. Each plate works in a different way to draw heat from the boats refrigerator and ice box area.

To find out more on Marine Refrigeration contact us today.

Eutectic Blower Units

Monday, July 27th, 2009

Dole’s Eutectic Blower Units combine the benefits of Dole’s eutectic holdover technology with the versatility of superior temperature control. The systems are created using Dole’s Eutectic Holdover Plates surrounded by a durable, lightweight enclosure. Fans mounted on the system circulate air over the plates and distribute cool air throughout the application.

The advantages of using the Eutectic Blower Unit system over the more passive Holdover Plate system is the thermostatic control and even distribution of air throughout the application. Dole currently produces three lines of Eutectic Blower Units with several options available for each.

For more information on these systems, catalogs are provided below or contact Dole.

Hybrid Refrigeration

Monday, July 27th, 2009

As opposed to Conventional Refrigeration units, Hybrid Refrigeration units work on a diesel/electric platform. Conventional refrigeration units are mechanical. A diesel engine in the unit directly drives the refrigeration unit’s compressor.

With hybrid refrigeration units, moving parts are not needed. The Engine drives the generator only when the reefer is in motion.

It is this generator that generates the power to run the refrigeration system’s components, such as the compressor. With a hybrid refrigeration unit, AC power is used when a reefer is parked. Conventional refrigeration units can also be converted to Hybrid Refrigeration units. An electric motor would need to be added to the unit to take over the job of providing the power that the diesel engine would normally provide.

Cold Plate Trucks

Monday, July 27th, 2009

DOLE continues to pioneer in the cold plate truck refrigeration field thus always assuring you of the finest in quality and the most in service for your refrigeration dollar.

Many years of excellent service and the increasing growth of DOLE users have continued to prove DOLE as one of the leaders in mobile cold plate truck refrigeration equipment. There is no substitute for experience, dependability and value.

Eutectic cold plates

Wednesday, July 22nd, 2009

Eutectic Cold Plates are one of the most reliable refrigeration systems available. Dole’s Eutectic Cold Plates provide the answer for mobile refrigeration and are a great alternative to mechanical refrigeration systems. Dole’s Eutectic Cold Plates are designed to maintain a constant temperature, or holdover, throughout the course of a day.

The plates are then “recharged” by connecting them to a condensing unit. After charging, the plates can maintain refrigerating temperatures for an entire work cycle. Dole’s Eutectic Cold Plates are designed and build with performance and economy in mind. Dole currently offers two holdover plate lines. Browse Dole’s two plate lines or contact Dole to see which Eutectic Holdover Plate is right for you.